 AUTO-RANGING AC INPUT AC-DC MULTIPLE OUTPUT 200 WATTS 19" COMPATIBLE DOUBLE EUROCARD SWITCHING POWER SUPPLIES HSU200 SERIES
FEATURES:
AUTO-RANGING AC INPUT 19" COMPATIBLE EUROCARD FORMAT MEET THE SAFETY STANDARDS EMI MEET CISPR PUB.22 & FCC CLASS A CE MARKING COMPLIANCE 12HP X 6U X160MM DOUBLE EUROCARD VMEbus STANDARD
TOTAL POWER INT'L
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: Auto-ranging 115Vac(90-132Vac) and 230Vac(180-264Vac). Transient threshold typ. 150Vac. Input Connector: DIN 41612 at rear. Input Frequency: 47-63Hz Inrush Current: Typ. 65.0A @ 230Vac. Input Current: Typ. 3.3A/115Vac & 1.6A/230Vac. Dielectric Withstand: Meet IEC950. EMI: Meet CISPR PUB.22 or FCC Class A. Hold-up Time: Typ. 26mS. Power OK: Installed Remote Inhibit: Installed. Over Temp. Protection (OTP): Installed (Thermostate). Power-On LED: Installed. Earth leakage: Typ. 0.3 mA @230Vac.
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart. Output Current: See Ratings Chart. Output Wattage: Typ. 200 Watts. Output Connector: DIN 41612 at rear. Line Regulation: Typ. 0.2%. Load Regulation: Main VO1 typ. 1.0%. Aux. VO2 typ. 1-2.0%(MA). Aux. VO3 typ. 2-3.0%(PR). Aux. VO4 typ. 2-3.0%(PR). Noise & Ripple: Typ. 1% peak to peak. OVP: Available at main VO1 & Aux.VO2.(latch). Adjustability: Available at VO1 & VO2. Remote Sense: Installed at main VO1. Overload Protection (OLP): Fully protected against output overload and short circuit. Typ. 130% full load. Consult the factory for OLP setting. Output LED Indicators: Installed for all outputs. Operating Temperature: 0 to +50C at full load. Derate linearly to +70C at half load. Storage Temperature: -20 to +85C. Temperature Coefficient: Typ. 0.04%/C. Cooling: Free air convection. Construction format: 12HPx6U compatible double Eurocard VMEbus standard.
GENERAL SPECIFICATION
Efficiency: Typ. 76-77.0%. Switching Frequency: Typ. 100K Hz. Circuit Topology: Forward circuit. Transient Response: Output voltage returns in less than 1.5mS following a 25% load change. Safety Standard: IEC950/UL1950 Class I. Power Density: 1.30 Watt / Cubic Inch.
Note: All measurements are at nominal input, full load, and +25C unless otherwise specified.
TOTAL POWER, INT. Tel: 877-646-0900 Fax: 978-453-7395 Email: sales@total-power.com http://www.total-power.com -1-
OUTPUT VOLTAGE/CURRENT RATINGS CHART
TRIPLE OUTPUT
MODEL NO. HSU200-T050II
(HSU200-32)
MAIN VO1 @# Typ. Volt. 20.0A 20.0A 20.0A 25.0A 5.0V 5.0V 5.0V 3.3V
AUX. VO2 @ Typ. Volt. 7.0A 3.5A 18.0A 17.0A 12.0V 24.0V 3.3V 5.0V
AUX. VO3 Typ. Volt. 1.0A 1.0A 1.0A 1.0A 12.0V 12.0V 12.0V 12.0V AUX. VO4 Typ. Volt. 1.0A 1.0A 1.0A 1.0A +12.0V +12.0V +12.0V +12.0V
HSU200-T050MI
(HSU200-33)
HSU200-T050DI HSU200-T033EI
QUAD OUTPUT
MODEL NO. HSU200-Q050III
(HSU200-40)
MAIN VO1 @# Typ. Volt. 20.0A 20.0A 20.0A 25.0A
"@" Adjustable.
AUX. VO2 @ Typ. Volt. 6.0A 3.0A 15.0A 14.0A +12.0V +24.0V +3.3V +5.0V
AUX. VO3 Typ. Volt. 1.0A 1.0A 1.0A 1.0A -12.0V -12.0V -12.0V -12.0V
+5.0V +5.0V +5.0V +3.3V
HSU200-Q050MII
(HSU200-42)
HSU200-Q050DII HSU200-Q033EII
Symbol: " " OVP built-in.
"#" Remote sensing.
"" Magnetic Amplifier.
"" Post Regulator.
MECHANICAL DIMENSIONS: MM [INCHES]
WEIGHT: 2.43Kg (5.35lb.)
INPUT & OUTPUT CONNECTORS PIN ASSIGNMENTS
AC INPUT TRIPLE/QUAD OUTPUT ASSORTED SIGNAL
SYS LOG. VO1 VO1 Reset INH. S(+) S(-)
ASSIGNMENT AC-L AC-N AC-G HSU200-T HSU200-Q
+VO1
+VO2
-VO3 +VO4 -
DC COM P2-18,20,22,24,26
NC
AC Fail P1-4 P1-4
P1-10,12,14,16,18 P1-8 P2-14 P2-32 P1-6 20,22,24,26 P1,10-12,24,16,18 P1-28 P1-30 P1-32 P2-4,6,8,10 P2-28,30 P2-16 P2-12 P2-18,20,22,24,26 P1-8 P2-14 P2-32 P1-6 20,22,24,26 P1-28 P1-30 P1-32 P2-4,6,8,10 P2-28,30 P2-16
Mating connector: DIN41612-H15 Female
TOTAL POWER, INT. Tel: 877-646-0900 Fax: 978-453-7395 Email: sales@total-power.com http://www.total-power.com -2-


▲Up To Search▲   

 
Price & Availability of HSU200-T

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X